Register to unlock your exclusive B2B prices. Register now
RCCB with re-closer - RED - 4 poles - 40 A - class A - 300 mA image 1
MD01 image 2
MD01 image 3
RCCB with re-closer - RED - 4 poles - 40 A - class A - 300 mA image 4
RCCB with re-closer - RED - 4 poles - 40 A - class A - 300 mA image 5
RCCB with re-closer - RED - 4 poles - 40 A - class A - 300 mA image 6

RCCB with re-closer - RED - 4 poles - 40 A - class A - 300 mA

In stock price (excl. VAT):
332,04 €
This price is valid until 2024-12-24
Price per m: 332,04 €
EAN: 3303430182672
MPN: 18267
Our warehouse: No Vendor stock: No
Per package: 1 Per box: 8 Per pallet: N/A
Technical data
Item condition New
Brand Schneider Electric
Categories Leakage protection
Country of origin PT
Mounting method DIN rail
Voltage type AC
Built-in depth 44.000 mm
Rated current 40.000 A
Rated voltage 400.000 V
Rated insulation voltage Ui 500.000 V
Number of poles 4.000
Rated fault current 300.000 A
Leakage current type A
Selective protection No
Short-circuit breaking capacity (Icw) 10.000 kA
Surge current capacity 0.250 kA
Pollution degree 2.000
Width in number of modular spacings 7.000
Short-time delayed tripping No
Explosion-proof No
Frequency 50 Hz
Degree of protection (IP) IP20
Connectable conductor cross section solid-core 1.500-2.500 mm²
Connectable conductor cross section multi-wired 1.500-2.500 mm²
With interlocking device Yes
Ambient temperature during operating -5.000-40.000 °C
Additional equipment possible Yes
Rated impulse withstand voltage Uimp 4.000 kV
Packing details
Packing level 1 3303430182672
Packing level 2 3303430182670
Downloads
Description
This Acti9 REDs is a modular residual current circuit breaker (RCCB) with recloser. It is a 4P circuit breaker with 40A In rated current, 300mA earth leakage sensitivity and A type protection class. This product protects against electrical shock by indirect contact and fire hazards. It disconnects of on-load electric circuits already protected against overloads and short-circuits. It restarts automatically after insulation monitoring of the downstream circuit. It is only used on TT and TN-S earthing grounding systems. The Acti9 REDs and REDtest versions are dedicated to tertiary,industrial and infrastructure applications. This product is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 630A. The (Inc/IΔc) conditional rated short circuit current is 15kA. It has a mechanical endurance going up to 4000 cycles. The Ue operational voltage is 400VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 14. The dimensions are (W) 125mm x (H) 98mm x (D) 79.5mm. The weight is 0.67kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 40°C. The storage temperature is from -20°C to 60°C.