Register to unlock your exclusive B2B prices. Register now
MD01 image 1
Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, lugs terminals image 2
Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, lugs terminals image 3
Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, lugs terminals image 4

Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 100kA, thermal magnetic multifunction, lugs terminals

Laohinnas (käibemaksuta):
178,24 €
Hind kehtib kuni 2024-12-24
Hind m kohta: 178,24 €
EAN: 3606481386540
MPN: GV4PEM03S6
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Bränd Schneider Electric
Kategooriad Mootori kaitselülitid
Päritoluriik PL
Harmoneeritud süsteemi kood 8536 2010 90
Laius 81.000 mm
Kõrgus 155.000 mm
Sügavus 116.000 mm
Tunnustalitlusvõimsus, AC-3, 400 V 1.500 kW
Sisseehitatud abilülitiga No
Nominaalne püsivool Iu 3.500 A
Sisseehitatud alapingevabastiga No
Pooluste arv 3.000
Tunnus-talitluspinge 0.000-690.000 V
Liigkoormuskaitse sättepiirkond 1.400-3.500 A
Kaitseaste (IP) IP40
Termokaitsega Yes
Peaahela ühendusviis Kruviühendus
Juhtelemendi liik Juhthoob
Väljalülituspõhimõte Elektrooniline
Nominaalne käitusvõimsus AC-3, 230 V korral 0.750 kW
Nimi lahutusvõime lühisel Icu 400 V AC korral 100.000 kA
Viivituseta lühisvabasti seadistuspiirkond 60.000 A
Faasirikketundlik Yes
Seadme ehitus Komplektne seade korpuses
Pakendamise üksikasjad
Pakkimistase 1 3606481386540
Downloads
Kirjeldus
TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 1.4-3.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).